A system integrator in Turin specified a polycarbonate robot cell window in 4 mm sheet because the fence supplier quoted it as standard. Six months later a gripper released a 3 kg casting at 1,800 mm height and the panel took the impact without breaking but pulled out of its frame, leaving a 200 mm gap at the bottom rail. Nobody was hurt. The next cell used 6 mm sheet and a bolted frame.
A decision sequence for the polycarbonate robot cell window
Start from the hazard, not the sheet. The question is what can leave the cell, at what mass and speed, and at what height. A window that only needs to stop a stray glove is a different product from one that must contain an ejected casting.
- Hazard: part mass, release velocity, height of the worst-case trajectory.
- Sheet: 6 mm polycarbonate minimum for a 1,200 mm panel; 8 mm above 1,500 mm spans.
- Frame: bolted aluminium profile with a 4 mm gasket, not a clip-in plastic trim.
- Interlock: switch on the access door frame, separate from the window fixing.
Panel spans, stiffness and the frame interface
A 6 mm polycarbonate panel on a 1,200 x 1,000 mm opening deflects about 12 mm under a 5 kJ impact, which is acceptable if the frame retains the panel. The same panel in a clip frame pops out at 4 mm deflection, because the clip releases before the sheet yields.
Panel stiffness scales with the cube of thickness, so going from 4 mm to 6 mm more than triples it. That is why the integrator in Turin saw a containment failure rather than a penetration failure.
Optical requirements in a robot cell
Operators need to see the gripper and the fixture, not the whole cell. A slight tint on the upper panels cuts glare from high-bay lighting, and clear panels at eye level keep colour and position readable during teach mode. Two different tints in one cell is a normal specification, not a mistake.

River People capability
River People cuts 6 mm and 8 mm polycarbonate to ±0.5 mm, supplies panels with a 25 mm edge margin free of holes, and can pre-fit gaskets for aluminium profile frames. Cell glazing sets are packed flat with edge protection and labelled per opening.
Send your cell layout and worst-case part data to oversales@rpplexiglass.com for a panel and frame schedule.
Fence glazing and machine guarding share the same retention rules, set out in the polycarbonate machine guard sheet guide.
Frequently Asked Questions
Does a robot cell window need to be laminated?
Only if the hazard review identifies a sharp or high-energy projectile that could penetrate a single sheet. For most handling cells, 6 to 8 mm monolithic polycarbonate is adequate.
Can polycarbonate be used in a welding cell?
Yes, but welding radiation degrades standard sheet. A UV-stabilised grade and a sacrificial shield in front of the panel are the usual approach.
How are panels cleaned without hazing?
A pH-neutral cleaner and a soft cloth. Solvent wipes and abrasive pads remove the hard coat and leave a haze that cannot be polished out on site.