The question that produced this page came from a lab manager: why do our multichannel pipettes drift out of calibration twice as fast as the single channel ones. The answer was not the pipettes. It was the bench. Every acrylic pipette rack in the room stored instruments lying flat in a drawer, tips forward, and the seals were being wetted by residual liquid between sessions.
Storage geometry is a calibration variable, and it is cheap to control.
Hang angle and the acrylic pipette rack bore
- Bore: 22 mm for 8 and 12 channel bodies, 18 mm for single channel
- Hang angle: 10 degrees from vertical, tips down
- Bore spacing: 30 mm centres for multichannel grips
- Body: 8 mm cast acrylic, bores reamed not drilled
- Base: 10 mm foot with a 15 mm rear upstand

A 10 degree hang lets liquid drain toward the tip rather than back into the seal, and it keeps the instrument from swinging when the rack is moved. Bores at 30 mm centres leave room for the grip of a 12 channel unit without the neighbouring body touching. Reamed bores, not drilled ones, because a drill margin gripping a plastic barrel marks it.
Weight and the acrylic pipette rack bench position
Six electronic pipettes weigh around 1.6 kg together with their tips. That load on a 5 mm sheet across a 400 mm span produces visible bow, and a bowed rack slides on a bench that is wiped twice a day. An 8 mm body with a 10 mm base holds flat, and the padded feet keep it in place without a clamp.
Cleaning and the acrylic pipette rack bores
Bores collect lint and dried buffer. A weekly wipe with a damp cloth and a cotton swab through each bore is enough, provided the bore has no internal shoulder where liquid can sit. We cut a 2 mm drain slot at the bottom of each bore so a rinse drains rather than pools, and we avoid solvent cement in the bore area because a cement bead is a trap for residue.
Labs order these in single bench units or as a trolley rack carrying twelve instruments. Send the instrument list and we will size the bores to the widest body in the set.
Send pipette models, channel count and bench depth to oversales@rpplexiglass.com and we will quote a rack in your layout.
A bench that stores pipettes usually stores sample tubes beside them, and the tube rack article covers bore sizing and the drain detail for a wet bench. acrylic blood tube racks covers that part of the specification.
Frequently Asked Questions
Should pipettes hang or stand?
Manual pipettes are stored hanging so residual liquid cannot travel toward the seal. Electronic models are usually stood, because their body is sealed. The rack geometry differs for each.
What bore diameter for a multichannel?
A 22 mm bore takes the body of most 8 and 12 channel units at the grip. Measure across the widest part of the body, then add 1 mm, rather than using the tip size.
Is 8 mm needed for a bench rack?
Yes when the rack carries more than six electronic pipettes. A 5 mm body bows under that load and the rack starts to walk on the bench.