A locker operator logged damage codes for a year across 2,100 polycarbonate parcel locker doors and found that 71 percent of replacements were caused by couriers kicking the door shut with a boot rather than by vandalism.
That single behaviour sets the requirement for a polycarbonate parcel locker door: impact at the lower third, repeated a hundred times a day, on a panel that must stay optically clear enough for a phone camera.
Impact point and the polycarbonate parcel locker door
- Door: 4 mm framed, 6 mm unsupported
- Lower third: 6 mm or an internal rib
- Hinge: two stainless hinges, 2 mm hole clearance
- Lock cut out: 45 mm, deburred both sides
The kick lands about 250 mm from the bottom edge, which is where a thin panel flexes most. A rib bonded across that zone, or 6 mm sheet, moves the failure from the panel to the frame.
Scanning, privacy and the polycarbonate parcel locker door
Couriers scan through the door to confirm the compartment is empty. A clear panel with a print band that leaves the centre open keeps that possible; a fully printed door forces the courier to open it, which slows the round.
Abuse testing before a bank goes live
A drop test with a loaded parcel bag at the lower third, repeated fifty times, predicts field life more accurately than any impact figure on a data sheet. It also reveals hinge creep, which is the second most common complaint.
River People cuts locker doors with lock and hinge cut outs, print bands and edge polishing to your bank drawing. Send the door schedule to oversales@rpplexiglass.com.
Send the locker bank drawing, door size and lock type to oversales@rpplexiglass.com for a quotation on cut doors with print.
Public doors take constant abrasion, and our polycarbonate surface wear notes explain how surface finish and handling combine to wear a panel.
Frequently Asked Questions
Why polycarbonate for a locker door?
Couriers drop parcels against the door and lever them with a scanner. Polycarbonate takes that without cracking or leaving sharp edges.
Clear or tinted doors?
Clear for courier scanning of the compartment, tinted where the contents should not be visible from the street.
What thickness for a 400 mm door?
4 mm is adequate for a framed door; 6 mm where the door is unsupported at the middle and takes kicks.